24V 660Ah LiFePO4 battery hi pallet jack-a power nghet, rei tak-dang thei tur atana siam a ni. Pallet handling fo leh material phurh chhunzawm zelna atan energy tha tak, consistent tak a pe a, downtime leh maintenance a ti tlem a ni. Integrated smart BMS, CAN communication support, leh durable construction hmangin he battery hian warehouse environment harsa takah him leh rintlak takin a thawk thei a ni.
Performance lama thatna a awm
Pallet jack hnathawhna atana power rintlak
Cycle Nun rei tak
Durable design hian cycle 4,000–6,000 a pe a, lead-acid battery pangngai aiin a let 10 thleng a pe chhuak thei a, pallet jack thlak leh enkawl senso pawh a tihtlem phah bawk.
Fast Charging a ni
Darkar 1–2 chhungin a charge kim vek a, chawlh rei vak lovah opportunity charging a support bawk a, pallet jack te chu downtime tlem berah a thawk thei reng a ni.
Temperature sang tak atanga hnathawh dan
Built to operate from -20℃to 60℃, subzero warehouse environment-ah pawh charging leh disharging rintlak tak neih theihna tur optional heating function a awm bawk.
Eco-Friendly Operation a ni
Lead-acid alternative nena khaikhin chuan zero emission leh energy efficiency sang zawk, warehouse kalpui dan nghet leh environment zawm dan tur a thlawp a ni.
Parameter a ni
| Electric lam thil chi hrang hrang | Mechanical lam thila thil chi hrang hrang | ||
| Voltage hming (Nominal Voltage) a ni | 25.6V | A len zawng (LxWxH) 1.1. | 787*336*787mm a ni |
| Nominal Capacity a ni | 660Ah a ni | Buk | 450kg a ni |
| Chakna thahrui | 16896Wh | Case Material a ni | SPCC |
| Mahni In chhuahtir | <3% per month | IP Rating a ni | IP54 a ni |
| Cycle Nunphung | >4000 vel a ni | Cell chi hrang hrang | NunphungPO4 |
| Charge & Discharge chungchang sawifiahna | Temperature & Thil dang sawifiahna | ||
| Charge Current a ni | 250A | Charge Temperature a ni | 0℃atanga 55℃/ 32℃F atanga 131℃F thleng a ni |
| Charge Cut-off Voltage a ni | 29.2V | Discharge Temperature a ni | -20℃atanga 60℃/ -4℃F atanga 140℃F thleng a ni |
| Charge Terminal/Connector a awm a | REMA | A dahna Temperature a ni | 10℃atanga 45℃/ 50℃F atanga 113℃F thleng a ni |
| Discharge Current a ni | 200A | Tarchhuak | LED hmanga entir a ni |
| Discharge Cut-off Voltage a ni | 22V | Inbiaktawnna | RS485/CAN a ni |
| Discharge Terminal/Connector a awm bawk | Anderson chuan a rawn ti a | Shipping Classification hrang hrang | UN3480, Class9 a ni |
He Battery hian Eng Nge A Tih Tak Tak
Hei hi lithium iron phosphate (LiFePO4) power system a ni a, electric pallet jack, high-volume warehouse leh distribution environment-a hnathawkte tan bik siam a ni. 660Ah capacity hian 16.9 kWh usable energy-a pe chhuak a, chu chuan pallet jack pangngai chu darkar 8-10 chhunga shift pumpui hmangin mid-shift charge ngai lovin power a pe thei a ni.

Operational Hours tihzauh a ni
He 24V 660Ah battery hian hnathawh chhunzawm zel nan energy output nghet tak a pe a, mid-shift battery thlak emaw backup battery emaw a ngai lo
Rapid Recharge Cycle hrang hrang a awm
Darkar 1–2 chhunga full charge hian scheduled break emaw shift transition emaw-ah planned opportunity charging a siam thei a, zan khata charge ngai lovin hmanrua te chu a awm reng thei a ni.
Temperature Resilience a ni
–20℃atanga 60℃thlenga stable performance hian cold-chain facilities leh high-temperature environment-ah rintlak taka hnathawh theihna a siam a, seasonal emaw regional extreme-a throughput mumal tak a thlawp a ni.
He Battery hian I Operation A Tidanglam Dan
Opportunity Charging: Shift khatah Operating Time tam zawk
Lead-acid battery hian charge leh cool{1}}down cycle rei tak a mamawh fo a, hei hian nitin hmanrua awm theihna a tikhawtlai emaw, facility-te chu spare battery fleet enkawl turin a nawr emaw a ni.
He lithium solution hian rapid charging a support a, routine break laiin runtime nasa tak a recover thei bawk. Minute 30–45 chhunga opportunity charge tawi tak chu battery thlak danglam emaw, zan khata charging window schedule emaw ngai lovin shift productivity tihzauh nan a tawk.
Consistent Power Output: A bul atanga a tawp thlengin a thawk tha
Lead-acid voltage hi discharge laiin a tlahniam zel a, shift a kal zel chuan lift speed leh travel performance a tihhniam phah a ni.
He battery hian 100% atanga 15% state of charge thlengin 25.6V nominal output a vawng reng a ni. Hei hian shift chhung zawngin pallet-handling performance mumal tak a siam a, hnathawh hun rei tak chhung pawhin.
Cold Storage Performance: Heating Break a awm tawh lo
Battery pangngai hian boruak lum takah chuan capacity nasa tak a hloh a, periodic warm-up break a mamawh fo bawk.
He battery hian integrated heating element a keng tel a , chu chu 0℃hnuaiah automatic in a activate thei a ni . -20℃thlenga full discharge capacity a vawng reng a, heating assist hmangin -10 degree-ah him takin a charge thei bawk.
Maintenance tihtlem: Tui pek loh, Corrosion awm lo, Equalization awm lo
Lead-acid battery te hian tui pek dan pangngai, terminal tihfai, leh periodic equalization te a mamawh a, hei hian labor hours hlu tak a hmang a ni.
He battery hian tui pek a ngai lo va, terminal tihfai a ngai lo va, equalization pawh a mamawh lo. Sealed construction hian corrosion a veng a ni. BMS hian over-discharge a veng a, chu chuan chhiatna a thlen reng thei a ni.
Deployment leh Integration tih a ni

Operator te inthlak danglamna
Operator lam atanga thlir chuan hmanrua hi a inang tlangin a thawk a ni. Control interface thar zir tur a awm lo. Thiltih danglamna langsar ber: operator-te chuan battery life tichhe lovin break laiin an charge thei tawh a ni.
Operator training-a update rawtna awmte chu:
- Opportunity charging kalphung (engtikah nge charge tur leh eng chen nge charge tur) .
- LED display hrilhfiahna (battery hian 5-segment state of charge a lantir)
- BMS error code a lo lang a nih chuan eng nge tih tur (a tlem hle a, mahse operator-te chuan report dan tur an hriat a ngai)
Installation kalpui dan tur
Battery dimension (787×336×787mm) hi pallet jack brand lian ber ber Crown, Yale, Raymond, leh Toyota model-a standard compartment sizing nen a inmil a ni. 450kg-a rit hian lead-acid nena inmil counterbalance a pe a, hmanrua hman dan dik tak a vawng reng a ni.
Physical installation ah hian minute 15-20 vel a ngai a:
Battery awmsa chu standard lifting equipment hmangin la chhuak rawh
Lithium battery chu compartment khatah dah rawh
Charging connector (REMA standard) chu connect rawh.
Discharge connector (Anderson standard) chu a inzawm khawm a.
BMS startup leh calibration (automatic process) tih finfiah .
Charging Infrastructure ngaihtuah turte
Lithium-compatible charger a ngai a ni. Lead-acid charger hi charge profile inmil lo a nih avangin hman theih a ni lo.
Option 1: Charger awmsa chu thlak leh rawh
Lithium battery nena inmilna famkim a pe a, charging chak tak a siam thei a, operational efficiency a ti sang thei bawk. He option hi hun rei tak-lithium technology lama inthlak tura ruahmanna siamtu facility tan a tha hle.
Thil tih theih 2: Lithium charging module hmanga siam thar leh tur
Tuna charging station awm mekte chu lithium-capable module hmanga tihchangtlun a ni. Hetiang approach hian upfront investment a tihtlem rualin fleet pumpuiah charging performance him leh dik tak a la tichiang reng a ni.
Performance tehkhin dan
| Thlentu | Hmanlai Lead-Acid | He LiFePO4 Battery hi a ni |
|---|---|---|
| Nun rei zawng (cycle) 1.1. | 300-500 | 4,000-6,000 |
| Charge hun (full) a ni. | Darkar 8-10 chhung a ni | Darkar 1-2 chhung a ni |
| Discharge thuk zawng a ni | 50% chuan a rawt a ni | 90% hman theih a ni |
| Maintenance darkar/kum khat chhung | 80-120 | 15-20 |
| Weight efficiency a ni | Baseline a ni | A rih zawng inang vek |
| Temperature awm dan tur | -10℃atanga 45℃thleng a ni | -20℃atanga 60℃thleng a ni |
| Voltage a awm dan a inang lo | A tlahniam chho zel | Flat discharge curve a ni |
| Memory effect a ni | Ni e (sulfation) . | Pakhatmah |
Key differentiator chu specification pakhat mah a ni lo-a dam rei zawk, charging chak zawk, leh zero maintenance te inzawmkhawm a ni.
Warranty leh Support a awm bawk
Kan battery specialist team inpe tak takte chuan lithium battery hi a service life chhung zawngin peak performance-in a thawk thei tih kan enfiah thin. Forklift hnathawh dan mumal leh felfai taka kalpui theih nan tanpuina kimchang tak kan pe a ni.
Comprehensive Support a ni
Technical lama tanpuina pek a ni
I lithium battery chungchanga harsatna awm apiang 24/7 phone leh email support
Preventive Maintenance tih a ni
Performance tihsan leh battery dam rei zawk nan check-ups neih fo thin
Performance tihchangtlun a ni
Customer mamawh bik a zirin battery hman dan leh charging strategy chungchangah kaihhruaina pe rawh.
Emergency-a tanpuina pek a ni
Technical lama harsatna beisei lohte rang taka chinfel theih nan emergency laiin fast-response support pe rawh.
Thutlukna siam
He battery hian hnathawhna atan awmzia a nei a, chutah chuan:
Pallet jack hian shift tam tak emaw darkar rei tak emaw a thawk thei: Charging chak leh cycle life rei zawk hian high-utilization scenario-ah hlutna nasa tak a pe a ni
Equipment downtime hian operational continuity a nghawng: Battery-related downtime tihtlem hian productivity leh workflow efficiency vawng reng turin a pui a ni
Operations hi temperature extreme-ah a thleng thin: Cold storage emaw hot warehouse environment-ah lead-acid performance a tlem thei
Maintenance resources a tlem hle: Zero-maintenance design hian hnathawk mamawh a tihtlem bakah staff te chu higher-value task atan a chhuah zalen bawk
He battery hi duhthlan tur dik tak a ni lo mai thei a, chu chu:
Equipment hi a hun laiin emaw, light-duty task atan emaw hman a ni: Extended lifespan hian low-utilization scenario-ah hlawkna tlemte chauh a pe a ni
Lead-acid infrastructure-ah investment lian tak a awm: Asset life la awm leh CAPEX strategy angin transitioning ruahman theih a ni
Initial capital expenditure hi tihkhawtlai a ni: Upfront cost sang zawk chu long-term operational savings nen tehkhin tur a ni
hot tags .: 24v 660ah pallet jack lithium battery, China 24v 660ah pallet jack lithium battery siamtu, supplier, factory